SpectroRadiometers-
Solar Measurement Systems
Solar Measurement Systems
Instruments for
Solar
Monitoring |
|
Solar
SpectroRadiometer
PDF Download
|
|
The BLACK-Comet
concave
grating spectrometers and the
Dual-DSR spectrometer configurations are the perfect tools for making
solar irradiance measurements. The solar irradiance monitors
are great for solar simulators and artificial lighting of all kinds. The
instruments are calibrated to measure
the spectral irradiance in units of watts per meter squared over the
wavelength range in nanometers. Currently there are
four model BLACK-Comet
irradiance monitors,
C
(190-850nm), CXR
(280-900nm), C-SR
(200-1080nm), CXR-SR
(220-1100nm). The Dual-DSR Solar configuration enables
irradiance measurements from 200-1700nm. This configuration combines
a BLACK-Comet concave grating spectrometer with a RED-Wave NIR
instrument to capture a complete UV-VIS-NIR irradiance spectrum all
in real time! Choose from the list
of StellarNet Solar monitoring configurations in the table at the
bottom of page. |
|
 |
|
SpectraWiz- Solar Irradiance Measurements
-
Absolute intensity
measurements watts/m2
-
µm
watts/cm2
- Lumens/m2
-- LUX
- Moles
per second
- Footcandles /m2
- Radiant Flux (watts)
- Luminous Flux (lumens)
- PAR- Photosynthetically
Active Radiation
- Correlated
Color Temperature
(CCT)
- Set Power Spectral
Density (PSD) range
- Solar Match Monitor

Solar Match Monitor-
View Press Release
The SpectraWiz® software now includes a new solar match panel
that is part of the Light Monitor application, that is used to
characterize and classify light emissions for solar simulators. The
Solar Match Monitor application calculates spectral
irradiance for each 100nm bin from 400-1100nm and compares the
results to the ideal percent for each bin range per IEC/JIS/ASTM.
The proximity of the measured data to the ideal values results in
classification of the solar simulator lamp from A through D. The
Light Monitor also measures UVabc regions below 400nm using both
U.S. and European standards.
NIST
Calibrations
-
StellarNet offers low cost NIST
calibration services over the spectral range 200-1700nm
-
Fast delivery: most system can be calibrated and shipped
within 1 week after receipt of order
-
Absolute calibration:
accuracy within 10% at detector
integration setting used for calibration
-
Certificate available:
documentation with NIST traceable serial numbers.

|
|
Why StellarNet
Solar SpectroRadiometers?
- Low cost -
Ruggedized - Research
quality
- Shock-proof - Permanently aligned
- Robust
- Miniature size
- NIST traceable
- SpectraWiz Software included Free
- USB-2 power and
interface to all notebook PCs
- Real time Solar spectrum analysis

BLACK-Comet
spectrometer comes in many
different models optimized for measuring solar irradiance, solar
simulators, and artificial light sources of all types.

DSR-CSR-512
Solar irradiance monitor configuration
Direct SUN
Light
October Noon – Tampa, FL

BLACK-Comet
Solar irradiance monitor configuration
Direct SUN
Light
December Noon – Tampa, FL |
|
Example Spectrum-
Normally
incident solar spectrum at sea level on a clear day.
Absorption and scattering levels change as the constituents
of the atmosphere change. Clouds are the most familiar example of
change; clouds can block most of the direct radiation. Seasonal
variations and trends in ozone layer thickness have an important
effect on the terrestrial ultraviolet level.

Episodic Data
capture of Sunset-
Solar spectra was recorded periodically during sunset. The
instrumentation used above is the standard BLACK-Comet model
spectrometer, a F600 fiber optic cable, and a cosine receptor.
Additionally, the spectrometer was spectroradiometrically calibrated
for low light conditions using a NIST traceable lamp and receptor
aperture. The episodic data capture shows clearly when the Sun has
dropped over the horizon and the spectral signature of distant
streetlights becomes the most significant feature of the spectrum.
StellarNet solar monitors may also be used to test solar simulators
and other artificial lights frequently used in the solar cell
testing, production, and quality control. |

StellarNet Cosine Receptors-
Solar Monitoring allow collection of
collect light with an 180 field of view using demountable diffusers
with ~10% loss. The
CR2-UVN
is a 1/4” diameter
cosine receptor using a
special polymer diffuser for 200-1700nm.
Cosine Receptor
PDF

SpectraWiz UV monitoring can provide UVa, UVb,
and UVc irradiance measurements as well as providing UVa/b ratios
and other useful values.
Power
and Interface
Portable spectrometers include
a USB-2 interface cable. |

|
Item |
BLACK-Comet and Dual-DSR Solar Configurations |
Price |
|
BLACK-Comet |
Concave
Grating spectrometer for UV-VIS.
C
(190-850nm) or
CXR
(280-900nm) |
$2,750 |
|
BLACK-Comet
"SR" |
Super Range
Concave
Grating spectrometer for UV-VIS-NIR. C-SR
(200-1080nm) or CXR-SR
(220-1100nm). |
$3,495 |
|
EPP2000-UVN-SR |
EPP2000 series spectrometer for
UV-VIS-NIR (200-1100nm) with plane grating |
$3,495 |
|
RED-Wave-NIR-512 |
NIR Spectrometer,
range 900-1700nm, with cooled 512
element PDA detector |
$13,125 |
|
RED-Wave-NIR-1024 |
NIR Spectrometer,
range 1000-1700nm, with cooled
1024
element PDA detector |
$17,695 |
|
DSR-CSR-512 |
BLACK-Comet model
C-SR (UV-VIS-NIR,
CCD) and
RED-Wave-NIR-512 (InGaAs PDA) for 200-1700nm |
$16,620 |
|
DSR-CSR-1024 |
BLACK-Comet model
C-SR (UV-VIS-NIR,
CCD) and
RED-Wave-NIR-1024
(InGaAs PDA) for 200-1700nm |
$21190 |
|
|
NIST Traceable
Calibrations
|
|
|
IRRADUVN-CAL |
SpectroRadiometric Calibration VIS-NIR for range
300-1700nm
|
$500 |
|
IRRAD-CAL |
SpectroRadiometric
Calibration VIS-NIR for range
300-1100nm
|
$250 |
|
IRRADUV-CAL |
SpectroRadiometric CalibrationUV for range
200-400nm |
$250 |
|
IRRADNIR-CAL |
SpectroRadiometric
CalibrationNIR for range
1100-1700nm
|
$250 |
|
IRRAD-CAL-DOC |
Optional
Irradiance calibration
certificate with NIST traceable serial numbers |
$125 |
|
|
Fiber Optic
Accessories for Irradiance Measurements |
|
|
CR2 |
CR2
Cosine Receptor for UV-VIS-NIR 1/4 inch diameter
and 180 degree field of view |
$125 |
|
CR2-AP |
Screw on 10% aperture for CR2,
allows measurement of light that is 10 times brighter |
$125 |
|
F600-VISNIR |
Armored 2 meter fiber optic cable attaches Receptor to
SpectroRadiometer |
$140 |
|
F600-UVVIS-SR |
Armored Solarization Resistant 600um fiber
optic cable - 2 meters |
$195 |
|
CRLENS |
Cosine receptor lens assembly reduces the
field of view from 180 ° to
4° |
$250 |
|
TP1 |
Tripod for mounting and positioning CR2/IC2 light receptors |
$49 |
*Note: actual spectrometer
range can be smaller than range described for
radiometric calibration
*Note all spectrometers for solar irradiance
measurements require NIST calibration and Irradiance Measurement
Accessories
*Please contact a StellarNet sales representative about more
spectrometer configurations
|
|
|
|
|