Developing Intelligence with Light  since 1993
Surf the New BLUE-Wave and GREEN-Wave Spectrometers ...  See us Nov6-8 in Nashville at OLA and Nov9-13 at LEOS in Newport Beach

     NEW!!! BLUE-Wave miniature Spectrometers

 

EPP2000 BLUE-Wave
Range
190-1150nm
The newly released StellarNet BLUE-Wave Spectrometers are fiber optic coupled instruments with a wide selection of models for  measurements in 190-1150nm wavelength ranges. Each unit contains a USB interface with a snap shot memory to provide instantaneous spectral image from the highly sensitive CCD with options for 2048 or 3648 elements. Various models provide a choice of grating range and slit resolutions.  New and improved electronics with a high speed 16-bit digitizer allows for fast data acquisition and a signal to noise of 1000:1!  Up to 8 units can be daisy chained together and are able to run simultaneously.  Additionally the new BLUE-Wave spectrometers can be powered directly from your PC USB-2 port.  A single strand fiber optic cable or probe assembly delivers input via standard SMA 905 fiber optic connector with a choice of cable lengths. The spectrograph optics are exceptionally robust in a vibration tolerant modular design, with no moving parts.

         


BLUE-Wave small size just 1x3x5 inches!! Compare the size with the EPP2000C

Free SpectraWiz Software
The powerful SpectraWiz® 32 bit spectrometer software is provided free of charge with every spectrometer instrument.  This includes drivers and customizable software for operation on Win95 / Win98 / WinNT / WinME / Win2000 /WinXP.    The SpectraWiz software is considered the "Swiss Army Knife of Spectroscopy and may be used to accurately measure wavelength emissions, reflectance, transmission, absorption, concentrations, and absolute intensities.  In addition to real-time spectroscopy,  SpectraWiz® has built-in applications for SpectroRadiometry, SpectroColorimetry, ChemWiz chemistry lab concentration analyzer, and UV level monitors.

 

  BLUE-Wave PDF Download
Blue-Wave  Price List


 Surf the 16-bit BLUE-Wave Spectrometers

The detachable spectrograph assembly and control electronics are protected inside a rugged metal enclosure, suitable for portable, process, and lab applications. Several units may be daisy-chained using a standard USB hub allowing simple configurations for dual and multi-beam applications in chemistry, spectroradiometry, and PORTA-LIBS.

Additional GBLUE-Wave measurement applications include emission wavelength monitoring /characterization of tunable lasers or LED’s and other sources such as elemental emissions from plasma & Laser Induced Breakdown Spectroscopy. Also Bragg grating technology enables optical sensing of many parameters including temperature and pressure. Thin film thickness measurements can be made using sample specular reflectance. The small size and weight makes the BLUE-Wave spectrometers just perfect for portable and OEM applications. CCD has best sensitivity and PDA has best SNR.



Optional Configurations
Units
may be daisy chained via USB-2 hub allowing simple configurations for dual and multi-beam process applications.  8 BLUE-Wave spectrometers can be operated at once!

Interface
The system includes a high speed plug & play interface using USB-1 connection.

        Specifications                       StellarNet Detector Information                How to Determine Spectral Resolution

 

Specifications                                                      BLUE-Wave   Spectrometers from  $2,500

Dynamic range:             2000:1 with 6 decades

Dimensions:                  1x3x5 inch = 25x75x125mm

Optical resolution:        see model table - to 0.2nm

Weight::                                    14 ounces

Detector type:               CCD, 2k/3k pixels   

Power consumption:      < 100 mA via USB port

Detector range:             200-1100nm (<350 extra$)

Interface:                      USB or USB Hub

Pixel size:                      14 x 200um or 7 x 200um

Detector Integration:     3ms to 65s

Diffraction Gratings:     Holographic & Ruled

Slit size options:           14, 25, 50, 100, 200um

Grating g/mm:              300, 600,1200,1800, 2400

Stray light:             <.1% at 435nm;<.05% at 600nm

Spectrograph:                f/4,  SymX-Czerny–Turner

Fiber optic input:          SMA905 0.22na single fiber

Order sorting filters:      Integrated & High Pass

Operating systems:        Win9x, WinXP, Vista

Signal to noise:             1000:1  

Software included:         SpectraWiz program & apps

Digitizer:                      16-bit

Also free programs for:  LabView,Excel+VBA,Delphi


 













The SpectraWiz software is included to accurately measure wavelength emissions, reflectance, transmission, absorption, concentrations, and absolute intensities.
 

      Standard Models

 

BLUE-Wave Spectrometer Configs     2048 pixel CCD/PDA detectors      Predicted Slit Resolving Resolutions

Model

Wavelength Range  (nm)

Grating
g/mm

Slit-200
nm res.

Slit-100
nm res.

Slit-50
nm res.

Slit-25
nm res.

Slit-14
nm res.

UV

200-600

1200

3.0

1.6

0.8

0.50

0.40

UV2

200-400

2400

1.5

0.8

0.4

0.25

0.20

UV3

220-350

3600

1.0

0.5

0.25

0.16

0.13

UVIS

300-1100

600

6.0

3.2

1.6

1.00

0.80

VIS

350-1150

 600

6.0

3.2

1.6

1.00

0.80

VIS2

380-780

1200

3.0

1.6

0.8

0.50

0.40

NIR

500-1150

600

6.0

3.2

1.6

1.00

0.80

NIR2

600-1000

1200

3.0

1.6

0.8

0.50

0.40

NIR2b

785-1150

1200

3.0

1.6

0.8

0.50

0.40

NIR3

550-840

1800

2.2

1.2

0.6

0.35

0.28

NIR3b

680-935

1800

2.2

1.2

0.6

0.35

0.28

NIR4

500-700

2400

1.5

0.8

0.4

0.25

0.20

NIR4b

600-800

2400

1.5

0.8

0.4

0.25

0.20

UVN

250-1100

600

6.0

3.2

1.6

1.00

0.80

UVNb

200-1050

600

6.0

3.2

1.6

1.00

0.80

StellarNet SpectraWiz Software                                   (PDF needs Acrobat Reader ver4+)  
StellarNet Spectrometer Features to Compare
             (PDF needs Acrobat Reader ver4+)
EPP2000 Portable Spectrometer General Information   (PDF needs Acrobat Reader ver4+)
StellarNet Spectrometer Accessories                            (PDF needs Acrobat Reader ver4+)

wpe1.jpg (1971 bytes) 

    BLUE-Wave Spectrometer Sample Spectra

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Reach us at +1-813.855.8687 Fax +1- 813.855.0394

[Products] [Price List] [Press Release] [Search] [Download] [Tech Specs] [Contact Us] [Corporate][Jobs] [Home]

Copyright © 2006 StellarNet, Inc.    All rights reserved.